Steel and Iron Products

Ductile Iron Fittings for Pressure Pipes for Water, Gas and Sewage

Strategic Recommendations Ductile Iron Fittings for Pressure Pipes for Water, Gas and Sewage (IS 9523:2000)

  • Start BIS Certification Immediately
    Apply for BIS certification under IS 9523:2000 without delay to ensure compliance before inspection or enforcement checks.
  • Engage ERA Compliance Experts
    ERA’s specialists provide full support for applications, testing, ISI marking, and audit readiness to achieve timely certification.
  • Reach Out for Support
    📧 cs@eraglobal.co.in | 📞 +91 9599296331 | 💬 WhatsApp: For assistance with BIS certification, testing, or inspection coordination.
  • Ensure ISI Marking & Test Certification
    All ductile iron fittings must carry the ISI mark and have a valid BIS Test Certificate before sale or dispatch. .
  • Track QCO Updates & Subscribe ERA Newsletter
    Stay updated with Gazette notifications, amendments, and BIS enforcement timelines by subscribing to the ERA Compliance Newsletter.
Ductile Iron Fittings for Pressure Pipes for Water, Gas and Sewage (IS 9523:2000)
Section Details
Product Name Ductile Iron Fittings for Pressure Pipes for Water, Gas and Sewage
Applicable Indian Standard (IS) No IS 9523:2000
Title of Indian Standard Ductile Iron Fittings for Pressure Pipes for Water, Gas and Sewage – Specification
Quality Control Order Covered under the Ductile Iron Pressure Pipes and Fittings (Quality Control) Order, 2009
Notification & Amendments • Original QCO: S.O. 1544(E), dated 25 June 2009 • Rescinded by: S.O. 2681(E), dated 23 October 2009 • Final QCO: S.O. 2749(E), dated 30 October 2009.
Final Enforcement Date 1st March 2010
Objective & Scope To ensure quality, safety, and standardization of ductile iron fittings used in water, gas, and sewage pressure systems.
Products Covered All types of ductile iron fittings, such as bends, tees, reducers, flanged adapters, and sockets designed for use in water, gas, and sewage pressure piping systems.
Exemptions Products manufactured exclusively for export are exempt, provided they conform to the specifications required by the foreign buyer (which must not be less than the Indian Standard).
Industries Impacted Water supply utilities, gas distribution companies, municipal sewage systems, ductile iron pipe manufacturers, and infrastructure contractors.
Mandatory Compliance Manufacturers must obtain a BIS licence under Scheme-I (ISI Marking) and ensure all products conform to IS 9523:2000 and bear the ISI mark.
Next Steps for Stakeholders Apply to BIS for certification, conduct product testing at BIS-approved labs, and ensure ISI-marked fittings before sale or distribution.
Legal Framework Provision & Enforcement Issued under Section 14 of the BIS Act, 1986; enforced by BIS and the Department for Promotion of Industry and Internal Trade (DPIIT).
Penalties Imprisonment up to 2 years or fine of not less than ₹2 lakh (extendable up to 10× the value of goods) or both. Continuing offences may attract an additional ₹5,000 per day fine.
Conclusion BIS certification under IS 9523:2000 is mandatory for ductile iron fittings to ensure safety, quality, and uniformity in infrastructure projects.
References/Annexures Gazette Notification S.O. 2749(E), dated 30.10.2009 – Ductile Iron Pressure Pipes and Fittings (Quality Control) Order, 2009.

Ready to start your certification journey?

Let us help you navigate regulatory challenges and achieve certification with ease. Leave us your details, and we’ll get back to you—or request a free consultation today.

ERA COMPLIANCE DIGEST

We don’t spam! Read our privacy policy for more info.

Get in touch with us today

Notification

The product “Ductile Iron Fittings for Pressure Pipes for Water, Gas and Sewage” (IS 9523:2000) is covered under the Ductile Iron Pressure Pipes and Fittings (Quality Control) Order, 2009, issued via Gazette Notification S.O. 2749(E) on 30th October 2009 by the Department for Promotion of Industry and Internal Trade (DPIIT), Ministry of Commerce & Industry. This Order superseded an earlier QCO issued via S.O. 1544(E) dated 25th June 2009, which was later rescinded by S.O. 2681(E) on 23rd October 2009.

Enforcement Timeline

  • The Order became effective from 1st March 2010, and non-certified fittings cannot be sold or distributed beyond this date.

Overview

This regulation was introduced under Section 14 of the BIS Act, 1986, mandating quality control and BIS certification for ductile iron pressure pipes and fittings to ensure safe and reliable infrastructure for water, gas, and sewage networks.

Objective & Scope

The primary aim of this standard is to ensure that all ductile iron fittings used in high-pressure applications for water, gas, and sewage systems meet consistent quality, strength, and performance parameters, thereby preventing leakage, corrosion, and failures.

Products Covered

The standard covers all ductile iron fittings such as bends, tees, reducers, sockets, and flanged connectors used in water, gas, and sewage pressure pipelines. These fittings are designed to match the corresponding ductile iron pressure pipes (IS 8329).

Exemptions Provided

Products manufactured exclusively for export are exempted from this Order, provided they meet foreign buyer specifications, which cannot be lower than the Indian Standard (IS 9523:2000).

Industries Impacted

  • This Order impacts the water supply, gas transmission, municipal sewage infrastructure, and industrial piping sectors, including ductile iron pipe and fitting manufacturers, EPC contractors, and utility service providers.

Mandatory Compliance Requirements

  • Manufacturers must obtain a BIS licence under Scheme-I (ISI Marking) for Ductile Iron Fittings conforming to IS 9523:2000. Every fitting must bear the BIS Standard Mark (ISI) before sale, storage, or distribution in India.

Next Steps for Stakeholders

  • Apply for BIS certification for IS 9523:2000 under Scheme-I.
  • Conduct internal quality audits and ensure test results match BIS parameters.
  • Label all products with the ISI mark before sale or dispatch.
  • Maintain traceability and test records to facilitate BIS inspection and audits.

Legal Provisions, Enforcement & Penalties

This Order is backed by Section 14 of the BIS Act, 1986, granting wide powers to enforcement authorities. Key provisions include:

  • Inspection, seizure, and sampling by designated officials such as State Industry Directors, Under Secretaries of DPIIT, or DIC General Managers.
  • Search and seizure actions governed by the Criminal Procedure Code (CrPC), 1973.
  • Penalties for false declarations, record tampering, and sale of uncertified products, which may include. 
  • Imprisonment up to 2 years, or
  • Fine of not less than ₹2 lakh (extendable up to 10× the value of goods), or both.
  • For continuing offences, an additional fine of up to ₹5,000 per day may be imposed.

Conclusion

The enforcement of IS 9523:2000 ensures high-quality ductile iron fittings in water, gas, and sewage systems, enhancing public safety and infrastructure reliability. All manufacturers must ensure BIS certification and proper marking before sale.

Ready to start your certification journey?

Let us help you navigate regulatory challenges and achieve certification with ease. Leave us your details, and we’ll get back to you—or request a free consultation today.

ERA COMPLIANCE DIGEST

We don’t spam! Read our privacy policy for more info.

Get in touch with us today

Scroll to Top